Kamstrup 602 modbus software

Kamstrup heat meter multical 602 rhi mid class 2 heat meters. If the meter has been opened and the seals have thus been broken, the meter is no longer valid for billing purposes. This increases flexibility and allows you to keep only one type of calculator in stock that can then be used for all kamstrup ultrasonic flow meters. These registered are then made available according to the included modbus memory map. Page 2 multical 602, type 602a must be connected to a temperature sensor pair type pt100. The modbus base module for multical ensures a simple integration from kamstrup s heat, cooling and water meters into a modbus based system. Kamstrup multical 602 and ultraflow ultrasonic heat meter. The legacy datagram is partly compatible with multical 602. Mbus top module and mbus base module, bacnet base module, n2 metasys base module, modbus base module.

We supply everything from a single meter to a complete system. Kamstrups multical 602 is an allpurpose heat calculator for heat and cooling together with almost any kind of pulsed flow meters and with 2 or 4 wired temperature sensor pairs. The software also allows logging to the csv files at. Continental control systems does not endorse any of these companies and we do not sell any software pro. This is useful for users looking for anything from assistance with modbus applications to complete turnkey automation installations. Multical 801 kamstrup as industrivej 28, stilling dk8660 skanderborg t. Chipkin gateways for kamstrup water and energy meters. Bacnet protocol implementation conformance statement pics. This data is being extracted with help of the advanced serial data logger modbus rtu,ascii or advanced tcpip data logger modbus tcp software only.

Driver for kamstrup usb ensemble water meter display information about data security and radiation lon for heat, cooling and water meters mbus master metertool and logview multical module programmer multiterm ready usb meter reader wireless mbus dongle. The module offers a number of different interface options especially for amr installations like wireless mbus, s0, modbus, dlmscosem. Multical 602, type 602d must be connected to a flow sensor with 24 v active pulse output. Modbus rtu slave module modbus communication module for multical 62601602801 data sheet. This unit is ideal for the measurement of energy consumption in family and multiple occupancy housing, housing associations, blocks of flats and small in. Bacnet protocol implementation conformance statement pics for multical 62601602801. Hi donald and fredrik, im interested to know if you did have any luck on your problems with the communication with the kamstrup multical 602 meters. Technical description mbus modules for multical 6162601602801 with multical 601 data package kamstrup as. Logging of kamstrup multical 601 heat meter submitted by boelle on fri, 05092014 17. Kamstrup multical 602 technical description pdf download. Kamstrup multical r module programmer free download. The meter can and must only be opened by kamstrup as. Industrivej 28, stilling 8660 skanderborg denmark tel. It consists of two individually controllable relays.

Modbus utility modbus utility is a free software provided. The volume is measured using ultrasonic technique which is proven as a longterm stable and accurate measuring principle. The calculator registers precise consumption throughout the whole lifetime. Multical 602, type 602d skal tilsluttes flowmaler med 24 v aktiv pulsudgang. Jan 18, 2016 hi donald and fredrik, im interested to know if you did have any luck on your problems with the communication with the kamstrup multical 602 meters. Ultraflow 54 dn150250 ultraflow 54 is a static flow sensor based on the.

Through our leadership, expertise and passion for partnership, we always think forward in pursuit of a brighter energy future. These relays are galvanically isolated and are used for switching minor loads on and o directly and threephase or larger loads via an intermediate breaker. The t3 series bacnet programmable controller is a low cost performer with big system features. Short direct sensors can also be fitted directly into all kamstrups ultraflow variants with g. For 12 bsp to dn300 pipe connection and applications requiring more communication options. For bulk discounts, complex purchases, or if youd prefer to talk to a consultant on the telephone please ring 01962 865142. Kamstrup multical 602 and ultraflow ultrasonic heat meter all purpose heating and cooling energy meter suitable for waterbased systems with temperatures from 2c to c. It provides application accessincluding opc data accessto modbuscompatible devices, enabling users to easily configure fast and reliable modbus connections. Suitable for waterbased systems with temperatures from 2c to. Kamstrup multical 602 heat meters with ultraflow 54 flow sensor. Kamstrup water and energy metering integration chipkin. The pc program is downloaded from kamstrups homepage and is easy to. Kamstrup smart metering solutions for water and electricity. Kamstrup heat meters kamstrup multical 602 rhi mid class 2 heat meters.

Feb 15, 2020 pulse with kamstrup multical 602 energy meter. Kamstrup optical eye and the pc application kamstrup multical module program mer. The file size of the latest setup package available is 417 kb. To access the download you must use the filezilla download manager program. How to make sure that the application sends requests and receives responses. Multical 602 and ultraflow ultrasonic energy meter. Multical 602, type 602abc kan tilsluttes flowmaler type ultraflow, elektronisk aftaster eller flowmalere med reedkontaktudgang. The gateway operates as a modbus tcp client that continously reads a number of select registers from the kamstrup 602 using the kmp protocol. The kamstrup multical 602 is an all purpose energy calculator for heat together with almost any kind of pulsed flow sensors and with 2 or 4 wired temperature sensor pairs. I have two kamstrup multical 801 modbus meters connected to a s71510sp with cm ptp communication module. Modbus maintains a database of companies that supply system integration services using the modbus protocol.

The kamstrup multical 603 heat meter comes with a builtin auto detect function, making it possible to replace the ultraflow when needed, without having to manually reconfigure the calculator. Metasys n2, modbus rtu and ethernetip for wired commu nication. The kamstrup multical 602 consists of sizes from 15mm to 300mm and offers the widest range of communication modules available in a heat meter. These nodes are regular pulse nodes with added support for kamstrup multical 602 energy meter. Go to the homepage and download and install the filezilla program download filezilla client. Logging of kamstrup multical 601 heat meter archived forum. The software lies within system utilities, more precisely device assistants. Node is connected by rs485 to a multical 602 energy meter and periodically reads certain values from the meter.

Shm are a main distributor for kamstrup heat, cooling and water meters. The amsmodbus module is a client interface module in the amplex module system. With the newest addition of modbus this meter is the most versatile heat meter available on the market. For general information concerning installation see cen report dscencr 582, heat meter installation. Instructions in selection, installation and use of heat meters.

Modbus power meter data logging easy method sunspeccompatible modbus power meters, inverters easy method modbus rtutcp polling. Multical 602, type 602a skal tilsluttes temperaturfolers. Furthermore, the factory guarantee no longer applies. Technical description mbus modules for multical 6162601. Kamstrup is world leading manufacturer of system solutions for smart energy and water metering. The modbus module is in full compliance with and included in the mid approval for multical. Bacnet protocol implementation conformance statement.

Rather than limiting the user to specific configurations a wide range of settings are allowed in this software. Node is connected by rs485 to a multical 602 energy meter and periodically reads certain values from. Download procedure kamstrup metertool and logview programs. Multical 602, type 602abc can be connected to flow sensor type ultraflow, electronic pickup, or flow sensors with reed switch output. Modbus rtu module for multical 602 kamstrup multical heat. The modbus base module for multical ensures a simple integration from kamstrups heat, cooling and water meters into a modbus based system. The multical 402 is a heat meter that utilises an ultrasonic flow meter and pt500 temperature probes. Suitable for waterbased systems with temperatures from 2c to c. Within reason the software does not limit the number of register channels that can be read from the modbus slave devices. See modbus register listing above for these values. There are three versions with various io configurations and can be expanded with external io modules to form a complete building automation solution. Multical 402 ultrasonic heat meter omni instruments. This article lists some of the available windows modbus software used by programmers for configuring and monitoring modbus devices, including the wattnode modbus. Kamstrup as industrivej 28, stilling dk8660 skanderborg t.

Ultraschall warmezahler multical 602 qn 2,5 baulange 190mm. To optain the filezilla program you can use the link below. S0, wireless mbus and modbus interfaces for digital meters. The amswmbus is a client interface module in the amplex module system. Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal heat meter, rhi compliant dn 150 250 spec sheet 1. The program multical module programmer is used for configuring. Configuring master station modbus rtu, modbus tcp, requests, response items. Kamstrup multical 602 installation and user manual pdf download. Please contact kamstrup for information on the availability of the above multical 403 variants on the individual markets.

Multical 602 energiezahler onlineshop mit fachberatung. Jun 25, 2014 kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal heat meter, rhi compliant dn 150 250 spec sheet 1. The chipkin modbus rtu gateway is a protocol gateway that converts data from modbus rtu and makes it available to devices that support a different protocol e. Stockshed uk distributor kamstrup multical 602 heat meters. Kamstrup multical r module programmer baixar gratis a.

1665 1593 1333 460 1597 993 1390 103 1578 1639 292 220 1468 1348 270 1308 35 1065 368 1613 347 1352 565 1380 539 1026 79 93 1414